Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

FGF13 CLIA Kit

Dieses Chemiluminescent ELISA-Kit wurde entwickelt für die quantitative Messung von Human FGF13.
Produktnummer ABIN5654205

Kurzübersicht für FGF13 CLIA Kit (ABIN5654205)

Target

Alle FGF13 CLIA Kits anzeigen
FGF13 (Fibroblast Growth Factor 13 (FGF13))

Reaktivität

  • 4
  • 2
  • 1
Human

Nachweismethode

Chemiluminescent

Methodentyp

Competition ELISA

Detektionsbereich

6.17 pg/mL - 500 pg/mL

Applikation

ELISA

Proben

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
  • Untere Nachweisgrenze

    6.17 pg/mL

    Analytische Methode

    Quantitative

    Spezifität

    This assay has high sensitivity and excellent specificity for detection of Fibroblast Growth Factor 13 (FGF13). No significant cross-reactivity or interference between Fibroblast Growth Factor 13 (FGF13) and analogues was observed.

    Sensitivität

    2.42 pg/mL
  • Kommentare

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Testdauer

    2 h

    Plattentyp

    Pre-coated

    Protokoll

    The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Fibroblast Growth Factor 13 (FGF13). A competitive inhibition reaction is launched between biotin labeled Fibroblast Growth Factor 13 (FGF13) and unlabeled Fibroblast Growth Factor 13 (FGF13) (Standards or samples) with the pre-coated antibody specific to Fibroblast Growth Factor 13 (FGF13). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Fibroblast Growth Factor 13 (FGF13) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Fibroblast Growth Factor 13 (FGF13) level in the sample or standard.

    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibroblast Growth Factor 13 (FGF13) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibroblast Growth Factor 13 (FGF13) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen

    Nur für Forschungszwecke einsetzbar
  • Handhabung

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Lagerung

    4 °C,-20 °C

    Informationen zur Lagerung

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Haltbarkeit

    4-8 months
  • Target Alle FGF13 CLIA Kits anzeigen

    FGF13 (Fibroblast Growth Factor 13 (FGF13))

    Andere Bezeichnung

    Fibroblast Growth Factor 13

    Hintergrund

    Gene Name: Fibroblast Growth Factor 13

    Gene Aliases: FHF2, Fibroblast Growth Factor Homologous Factor 2

    Gen-ID

    2258

    UniProt

    Q92913

    Pathways

    Regulation of Cell Size
Sie sind hier:
Chat with us!